Sign In | Join Free | My burrillandco.com
Home > Water Cooled Scroll Chiller >

JLSK-60HP Industrial Water Chiller Machine For Electroplating Electrophoresis

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap JLSK-60HP Industrial Water Chiller Machine For Electroplating Electrophoresis from wholesalers
     
    Buy cheap JLSK-60HP Industrial Water Chiller Machine For Electroplating Electrophoresis from wholesalers
    • Buy cheap JLSK-60HP Industrial Water Chiller Machine For Electroplating Electrophoresis from wholesalers
    • Buy cheap JLSK-60HP Industrial Water Chiller Machine For Electroplating Electrophoresis from wholesalers

    JLSK-60HP Industrial Water Chiller Machine For Electroplating Electrophoresis

    Ask Lasest Price
    Brand Name : JIALIS
    Model Number : JLSK-60HP
    Certification : CE/ISO9001
    Price : Discuss
    Payment Terms : T/T
    Supply Ability : 100 units per month
    Delivery Time : 15 days
    • Product Details
    • Company Profile

    JLSK-60HP Industrial Water Chiller Machine For Electroplating Electrophoresis

    JLSK-60HP Water-Cooled Scroll Chiller Electroplating, Electrophoresis, Hydraulic Pressure, Mold Cooling


    Product Description:


    Water-cooled open-type chiller is a cooling device used in refrigeration and air-conditioning systems. Its working principle is to use a compressor to compress the refrigerant into a high-temperature and high-pressure gas, and then cool it into a low-temperature and low-pressure gas through a heat exchanger, and then pass through After the expansion valve is adjusted, it enters the evaporator to make it absorb the heat in the air and cool it down, and finally passes through the compressor to and fro to form a refrigeration cycle.

    Different from closed-type chillers, water-cooled open-type chillers use public water sources (such as tap water) in the cooling process, and circulate water through cooling towers and cooling water pipelines to cool the refrigerant, thereby achieving cooling effects. At the same time, the cooling water of the water-cooled open chiller will be sprayed on the cooling tower during the cooling process to form water mist, so it is called "open type".



    Production Features:


    Water-cooled open chiller is a cooling equipment used in industrial and commercial air-conditioning systems, and its features are as follows:

    1.High efficiency and energy saving: The water-cooled open chiller adopts high-efficiency compressors and heat exchangers, which can quickly cool down during operation, improve the efficiency of the air conditioning system, and reduce energy consumption costs.


    2.High reliability: The design and manufacture of the water-cooled open chiller adopts proven technology and materials, which has high reliability and can maintain stable performance during long-term operation.


    3.Space-saving: The water-cooled open chiller is small in size and takes up less space, so it can be used in places with limited space.


    4.Easy maintenance: The water-cooled open chiller has a simple structure, easy maintenance, and low maintenance costs.


    5.Environmental protection and energy saving: The water-cooled open chiller uses environmentally friendly refrigerants, which will not pollute the environment, and at the same time can reduce energy consumption and achieve the purpose of energy saving and emission reduction.


    6.Wide range of applications: Water-cooled open chillers are suitable for air-conditioning systems of various scales and can meet the needs of different applications.


    Working Principle:


    The water-cooled scroll chiller is a chiller that uses water cooling. It adopts scroll compressor technology, which can generate high pressure in a small space, making the cooling effect more excellent. The water-cooled scroll chiller is mainly composed of a compressor, a condenser, an expansion valve and an evaporator. Its working principle is as follows:


    1.Compressor: The water-cooled scroll chiller uses a scroll compressor to compress low-temperature and low-pressure refrigerant gas into high-temperature and high-pressure gas.


    2.Condenser: The high-temperature and high-pressure gas exchanges heat with the external water through the condenser, so that the refrigerant gas is cooled and condensed into a high-pressure liquid.


    3.Expansion valve: The high-pressure liquid is depressurized through the expansion valve, becomes a low-temperature low-pressure liquid, and then enters the evaporator.


    4.Evaporator: The low-temperature and low-pressure liquid exchanges heat with the outside air through the evaporator, thereby absorbing the heat in the air and evaporating the refrigerant liquid into a low-temperature and low-pressure gas.


    5.Cycle: Low-temperature and low-pressure gas enters the compressor to start a new refrigeration cycle.


    Compared with air-cooled chillers, water-cooled scroll chillers use water cooling, so a water source is required. However, compared with air, water is less compressible, so the cooling effect of water-cooled scroll chiller is more stable, the noise is lower, and it is also more environmentally friendly. In addition, scroll compressors are more efficient than traditional reciprocating compressors, and can generate high pressure in a small space, resulting in better cooling effects.


    Techinical Parameters:


    ModelJLSK-5HPJLSK-10HPJLSK-15HPJLSK-20HPJLSK-25HPJLSK-30HPJLSK-40HPJLSK-50HPJLSK-60HP
    Cooling capacityKW15.53146.56277.593124155186
    Kcal/h13,7502750041,25055,00068,75082,500110,000137,500165,000
    Temperature range5~35(Below 0 can be customized)
    Power supply3N-380V/415V 50HZ/60HZ
    Total powerKW4.18.112.416.520.224.632.240.348.5
    Chilled waterm³/h2.65.58.210.813.61621.226.531.8
    Cooling waterm³/h3.26.810.313.917.220.527.334.240.8
    CompressorTypeFully enclosed scroll/piston
    Start methodY-△启动
    Output PowerKW3.87.511.31518.822.53037.545.5
    RefrigerantTypeR-22/R407C/R410A
    Control methodTemperature Sensing External Pressure Equalizing Expansion Valve
    Filling volumeKG2.557.510.512.51520.22530
    EvaporatorTypeshell and tube
    DiameterG1.5″G2″G2.5″G3″
    CondenserTypeshell and tube
    DiameterG1.5″G2″G2.5″G3″
    Protective deviceHigh and low voltage switch, antifreeze protection, soluble plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
    DimensionsLmm95012601600160018501850225022502600
    Wmm500650650700700700850850850
    Hmm122012201300130013001360142014201420
    Unit weightKG150280460520600850105013801550


    Application Industry:


    Water-cooled open chillers are widely used in refrigeration and air-conditioning systems in various industries, including but not limited to the following:

    1.Industrial refrigeration: Water-cooled open chillers are widely used in the field of industrial refrigeration, such as cold storage, pharmaceuticals, chemicals, plastics, rubber, electronics, metallurgy, food, beverages and other industries.


    2.Commercial air conditioning: Commercial buildings such as large shopping malls, office buildings, hotels, hospitals, etc. need to use water-cooled open chillers to maintain indoor temperature.


    3.Transportation: Water-cooled open chillers are also widely used in the field of transportation, such as the cooling system of high-speed rail, aircraft, ships and other vehicles.


    4.Energy field: Water-cooled open chillers are also widely used in the energy field, such as nuclear power plants, wind power generation, solar power generation and other fields.



    Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

    Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry


    Upport and Services:


    Air Cooled Chiller technical support and service includes:

    1. 24/7 customer support
    2. Remote guidance installation and maintenance
    3. Remote Diagnostics and Troubleshooting
    4. Phone/Email Advice and Guidance
    5. User friendly documentation and manuals
    6. Software Updates and Upgrades
    7. Cost price of spare parts and consumables


    Packing and Shipping:


    Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.


    Product Maintenance:


    Water-cooled scroll chiller is an important refrigeration equipment. In order to ensure its normal operation and prolong its service life, regular maintenance is required. The following are the matters needing attention in the maintenance of the water-cooled scroll chiller:


    1.Regular cleaning: The water-cooled scroll chiller needs to be cleaned regularly, including cleaning the condenser and evaporator and other components to ensure that its surface is clean and free from dirt or dust, so as to ensure the cooling effect.


    2.Clean the filter screen regularly: The filter screen needs to be cleaned regularly to avoid dust and dirt from clogging the filter screen and affecting the cooling effect.


    3.Regularly replace the refrigerant: The refrigerant needs to be replaced regularly to ensure its cooling effect.


    4.Regular inspection of pipes: Regular inspection of pipes is required to ensure that they are not leaking or damaged, so as to avoid refrigerant leakage and affect cooling effect and safety.


    5.Regular inspection of electrical components: Regular inspection of electrical components is required to ensure good electrical connections and normal operation of electrical equipment to avoid safety accidents caused by electrical failures.


    6.Regular inspection of scroll compressors: Scroll compressors need to be inspected regularly to ensure their normal operation and avoid safety accidents caused by compressor failures.


    7.Regularly check the surrounding environment of the unit: It is necessary to regularly check the surrounding environment of the unit to ensure that there are no sundries or obstacles to avoid affecting the normal operation of the unit.


    In short, the maintenance of the water-cooled scroll chiller is very important. It needs regular cleaning, replacement of refrigerant, inspection of pipelines, electrical components and scroll compressors, etc. to ensure its normal operation and safety. At the same time, it is necessary to pay attention to regular maintenance, and do not overuse or overload the operation to avoid damage to the equipment.


    Quality JLSK-60HP Industrial Water Chiller Machine For Electroplating Electrophoresis for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)