Sign In | Join Free | My burrillandco.com
Home > Water Cooled Screw Chiller >

JLSW-30D 380V 50Hz Water Cooled Screw Chiller Machine For Filling Machinery

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap JLSW-30D 380V 50Hz Water Cooled Screw Chiller Machine For Filling Machinery from wholesalers
     
    Buy cheap JLSW-30D 380V 50Hz Water Cooled Screw Chiller Machine For Filling Machinery from wholesalers
    • Buy cheap JLSW-30D 380V 50Hz Water Cooled Screw Chiller Machine For Filling Machinery from wholesalers

    JLSW-30D 380V 50Hz Water Cooled Screw Chiller Machine For Filling Machinery

    Ask Lasest Price
    Brand Name : JIALIS
    Model Number : JLSW-30D
    Certification : CE/ISO9001
    Price : Discuss
    Payment Terms : T/T
    Supply Ability : 100 units per month
    Delivery Time : 20 days
    • Product Details
    • Company Profile

    JLSW-30D 380V 50Hz Water Cooled Screw Chiller Machine For Filling Machinery

    JLSW-30D Water Cooled Screw Chiller Liquid Food Machinery, Filling Machinery, Filling And Palletizing


    Product Description:


    Food filling machinery chiller is a filling equipment specially used in the food industry to provide cooling water for food filling machines. Its working principle is similar to that of general filling mechanical chillers, but there may be some special requirements in design and material selection to ensure compliance with food safety and hygiene standards.



    Production Features:


    Here are some possible features and considerations:

    1. Material selection: Food filling machinery chillers are usually made of stainless steel or other materials that meet food-grade standards to ensure that the equipment has good corrosion resistance and food safety.


    2. Hygienic requirements: The food industry has very strict hygienic requirements for equipment. Therefore, food filling machinery chillers usually have an easy-to-clean and disinfect design to ensure a sterile and odor-free cooling water supply.


    3. Temperature control: During the food filling process, some products need to be filled at a specific temperature. Therefore, food filling machinery chillers may need to have precise temperature control functions to meet the requirements of different food products.


    4. Safety: Food filling machinery chillers should be designed with safety in mind, including safety designs to prevent cooling water from contacting food and preventing electric leakage.


    5. Automation and control system: Food filling machinery chillers may be equipped with advanced automation and control systems to monitor and control the temperature, flow and other parameters of cooling water to ensure stable operation of the equipment and efficient filling.


    It needs to be operated and installed according to the specific food filling machinery chiller model and manufacturer's requirements. It is recommended to read the operation manual of the equipment in detail before use, and follow the relevant food safety and hygiene standards to ensure the safe operation of the equipment and the guarantee of food quality. If necessary, it is best to consult relevant professionals or equipment manufacturers for accurate guidance.


    Working Principle:


    The working principle of the water-cooled screw chiller mainly includes four processes of compression, condensation, expansion and evaporation.
    1.Compression process: Under the action of the screw compressor, the refrigerant is compressed into a high-temperature and high-pressure gas, while absorbing the surrounding heat.


    2.Condensation process: High-temperature and high-pressure refrigerant enters the condenser, and through contact with cold water or surrounding air, it emits heat and cools into a high-pressure liquid.


    3.Expansion process: The high-pressure liquid refrigerant enters the evaporator through the throttle valve, the pressure drops suddenly, and the liquid refrigerant expands into a low-pressure refrigerant while absorbing the surrounding heat.


    4.Evaporation process: The low-pressure refrigerant enters the evaporator, absorbs surrounding heat through contact with water or air, turns into a low-temperature and low-pressure refrigerant, and returns to the compression process.


    Through such a cycle process, the water-cooled screw chiller can deliver cold water to the area that needs to be cooled to achieve the effects of cooling, dehumidification and keeping the air fresh. At the same time, the water-cooled screw chiller will also emit a certain amount of heat, which needs to be dissipated through cooling towers or other heat dissipation equipment to ensure the normal operation of the system.


    Techinical Parameters:


    ModelJLSW-30DJLSW-40DJLSW-50DJLSW-60DJLSW-80DJLSW-100DJLSW-120DJLSW-150D
    Cooling capacityKW/h100140180200260370430550
    TR28.539.851.256.973.9105.2122.3156.4
    Temperature range5℃~35℃(Below 0℃ can be customized)
    Power supply3N-380V/415 50HZ/60HZ
    CompressorTypeSemi-hermetic screw
    PowerKW22303641568093118
    electric currentA3951657195135156198
    RefrigerantTypeR22/R407c
    Control methodTemperature Sensing External Pressure Equalizing Expansion Valve
    filling volumeKg16.522.227.533.444.455.666.582.6
    Evaporatorshell and tube
    Flowm³/h17.222.429.33343.964.275.295.3
    DiameterinchG2.5"G3"G3"G3"G3"G4"G4"G4"
    CompressorTypeshell and tube
    Flowm³/h22.429.235.242.957.884.3101.1123.9
    DiameterinchG2.5"G3"G3"G3"G3"G4"G4"G4"
    Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
    Machine sizeLmm22002250235024502500290030003000
    Wmm80080080090090090015001500
    Hmm15001600165017501800185015001550
    Unit weightKg960990126013801520183021502580

    ModelJLSW-170DJLSW-200DJLSW-230DJLSW-260DJLSW-280DJLSW-310DJLSW-350DJLSW-400D
    Cooling capacityKW/h6207108309301020113012701530
    TR176.3201.9236264.4290321.3361.1435
    Temperature range5℃~35℃(Below 0℃ can be customized)
    Power supply3N-380V/415 50HZ/60HZ
    CompressorTypeSemi-hermetic screw
    PowerKW130150175200225250281325
    electric currentA218253295335390432480553
    RefrigerantTypeR22/R407c
    Control methodTemperature Sensing External Pressure Equalizing Expansion Valve
    filling volumeKg93.8111.2126.8144.1155.4170.9193.2220.9
    Evaporatorshell and tube
    Flowm³/h108.6126.3144.9163.8176.4196.5222.4252.6
    DiameterinchG5"G5"G6"G6"G8"G8"G8"G8"
    CompressorTypeshell and tube
    Flowm³/h141.1166.2190.9215.8232.4258.6290.8333.2
    DiameterinchG5"G5"G6"G6"G8"G8"G8"G8"
    Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
    Machine sizeLmm36003600360036503650370037004200
    Wmm15001500150016001650175017501750
    Hmm16501650170017001700175018001800
    Unit weightKg30503200345037804060433046004820


    Application Industry:


    It is widely used in pharmaceutical, chemical, food, grease, coating, electroplating, cold storage, plastic, chemical fiber, commercial concrete, laser, purification workshop, mechanical processing and other industries. It can precisely control the temperature required by modern industrial manufacturing, greatly improving efficiency and product quality. JIALIS chiller is easy to operate, reasonable in design and superior in quality, with more than 100 models, it is the best choice for modern industrial refrigeration.



    Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

    Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry


    Upport and Services:


    Air Cooled Chiller technical support and service includes:

    1. 24/7 customer support
    2. Remote guidance installation and maintenance
    3. Remote Diagnostics and Troubleshooting
    4. Phone/Email Advice and Guidance
    5. User friendly documentation and manuals
    6. Software Updates and Upgrades
    7. Cost price of spare parts and consumables


    Packing and Shipping:


    Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.


    What are the cleaning and disinfection methods for food filling machinery chillers?


    The cleaning and disinfection of food filling machinery chillers are very important to ensure the hygiene of the equipment and food safety. Here are some common cleaning and disinfection methods:

    1. Cleaning procedure:

    - De-energize and disconnect power to the chiller mechanical chiller.
    - Make a cleaning solution using detergent and moderately warm water.
    -Use a soft cloth or brush to spread the cleaning solution evenly on the interior and exterior surfaces of the cold water mechanical chiller.
    - Take care to clean all visible and hidden areas of the mechanical chiller, including tanks, pumps, pipes and filters, etc.
    - Pay attention to clean the condenser and evaporator to ensure the smooth operation of the cooling system.
    - Thoroughly rinse the inside and outside of the cold water mechanical chiller with clean water to ensure that the cleaning agent is completely removed.
    - Wipe the surface of the cold water mechanical chiller to make sure it is dry.


    2. Disinfection procedure:

    - Prepare an appropriate disinfectant solution, food grade disinfectant or bleach can be used.
    - Spread the disinfectant solution evenly on the interior and exterior surfaces of the cold water mechanical chiller.
    - Ensure sanitizer adequately contacts all surfaces and sanitizes for the specified time.
    - Thoroughly rinse the interior and exterior of the cold water mechanical chiller with clean water to ensure complete removal of the disinfectant.
    - Wipe the surface of the cold water mechanical chiller to make sure it is dry.


    Note that specific methods of cleaning and disinfection may vary with different equipment and guidelines. It is important to follow the cleaning and sanitizing guidelines provided by the equipment manufacturer and follow strict food safety standards. Also, make sure to use food-safe cleaners and sanitizers in the correct concentrations and procedures. It is best to consult a professional or the equipment manufacturer for precise cleaning and disinfection instructions, if necessary.


    Quality JLSW-30D 380V 50Hz Water Cooled Screw Chiller Machine For Filling Machinery for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)